A worker safety program means that at the end of the day, everyone gets to go home. For any industry, precautions must be maintained to ensure worker safety. In the electrical utility industry these precautions start with a very detailed set of “safety Rules” with every worker following the procedures outlined in those rules. Power line technicians do not always get the luxury of de-energizing circuits before they work on them. It is for this reason they must follow strict “hot line” work procedures and adhere to very specific limits of approach distances. 

Occupational health and safety legislation in every province and territory ensures these worker safety programs are up to date. For this legislation, a revised standard has become available to help those jurisdictions ensure that the lights can stay on without the heavy cost of worker injuries or worse. 

Electric utility workplace

ULC Standards issued a standard bulletin in December 2014 to announce the publication of the second edition of CAN/ULC-S801, Standard on Electric Utility Workplace Electrical Safety for Generation, Transmission, and Distribution. The development of this second edition was funded by the Canadian Electricity Association (CEA) This CAN/ULC-S801 standard is recognized as a national standard of Canada, has been approved by the ULC Standards Committee on Electric Utility Workplace Electrical Safety. Presently, Alberta Workplace Health and Safety is in the middle of a public consultation on their new Occupational Health and Safety Code whereby they are proposing to reference the CAN/ULC-S801 Standard. To participate in this consultation, go to http://alberta.ca/publicconsultations.cfm.

CAN/ULC-S801 applies to the construction, operation, maintenance and replacement of electric utility systems that are used to generate, transform, transmit, distribute or deliver electrical power or energy to consumer services or their equivalent.
This includes:

• equipment located in easements, rights of way, or in other recognized agreements
• equipment located on property owned or leased by the electric utility for the purpose of communication, metering and control of electrical power or energy
• service drops or laterals, associated metering, and street lighting under the exclusive control of electric utilities
• facilities used to generate electrical power or energy for electric utility systems
• voltage levels up to 800 kV AC line-to-line (L-L) and 600 kV DC

The purpose of this standard is to provide safety performance requirements for electric utilities, workers and employers involved in work on or near electric generation, transmission and distribution systems.

This second edition CAN/ULC-S801 includes:

• new and updated sections on risk assessment and electric arc hazard
• informative material on equipotential bonding and grounding, fall protection and use of PPE
• modified content that better aligns with the IEC Canadian adaptations Live Working standards

Electric arc flash hazard

Electric arc hazard is defined within the standard as follows:

“a potential harm from an energy release from an electrical arc usually caused by a short circuit or equipment failure in electrotechnical work.”

Note 1, The possibility of an arc flash (electric arc) hazard exists when live electrical conductors or parts are exposed and when they are inside of equipment even when guarded or enclosed, if a worker is interacting with the equipment in a way which could cause an electric arc. Under normal operating conditions, enclosed energized equipment that has been properly designed, installed and maintained is not likely to pose an electric arc hazard.

Note 2, The hazards may include thermal effects, noise, pressure wave effects, ejected parts effects, molten metal, optical and other effects. Different PPE may be required to protect from different effects. The risk assessment must consider all the potential effects.

The standard requires that when personnel work in proximity to energized equipment above 50 V AC, all potential sources of arc flash should be identified and risk assessed. Parameters to consider when performing an arc-flash assessment should include but be not limited to fault current, fault clearing time, arc length, distance to the arc and system voltage. Consideration shall also be given to very low fault energy areas as well as very high. Low fault currents can result in very long clearing times and may give higher total incident energies than high fault currents with very fast clearing times.

Additionally the standard outlines alternative or additional measures to minimize worker exposure where incident energy cannot be reduced to a point below the “lowest practicable level” — assumed to fall below 167.5 kJ/m2 (40 cal/cm2) at the normal (or working) distance from specific apparatus — where commonly available arc-rated PPE can be used to protect workers.

Equipotential bonding and grounding

While grounding in the power line context is the physical connections of isolated lines and equipment to ground, equipotential grounding physically interconnects conductive parts (lines and equipment) to maintain a common potential in order to limit the current that can pass through the body of a utility worker to a level that will not cause harm. This is the practice of keeping the worker's extremities (hands and feet) at the same voltage or as close as possible to eliminate the flow of current through the body. 

The CAN/ULC-S801 standard provides several examples of equipotential grounding calculations whereby the current through the electrical workers body is kept well below the value at which ventricular fibrillation would occur. Keep in mind there will always be some current flow through the worker, in inverse proportion to the resistance of the body path as compared to the parallel equipotential bond path. The intent is to keep the current sufficiently low that there are no harmful effects to the worker.

Live working standards

Live working standards, procedures and equipment is extremely specialized and procedurally driven. Section 7 of the CAN/ULC-S801 standard provides direction and references for live work on low, medium and high voltages systems, including insulating gloves (rubber gloves), insulating sticks and bare handed work.
Additional standards and references include:

• CAN/ULC-60855-09, Live Working - Insulating Foam-Filled Tubes and Solid Rods for Live Working (IEC 60855:1985, MOD) 

• CAN/ULC-60895-09, Live Working - Conductive Clothing for Use at a Nominal Voltage up to 800 kV a.c. and ± 600 kV d.c. (IEC 60895:2002, MOD) 

• CAN/ULC-60903-09, Live Working - Gloves of Insulating Material (IEC 60903:2002, MOD) 

• CAN/ULC-60984-08, Sleeves of Insulating Material for Live Working (IEC 60984:2002, MOD) 

• CAN/ULC-61112-09, Blankets of Insulating Material for Electrical Purposes (IEC 61112:1992, MOD) 

• CAN/ULC-61229-09, Rigid Protective Covers for Live Working on a.c. Installations (IEC 61229:2002, MOD) 

• CAN/ULC-61230-09, Live Working - Portable Equipment for Grounding and Bonding (IEC 61230:2008, IDT) 

• CAN/ULC-61235-09, Live Working - Insulating Hollow Tubes for Electrical Purposes (IEC 61235:1993, IDT) 

• CAN/ULC-61243-2-09, Live Working - Voltage Detectors - Part 2: Resistive Type to be Used for Voltages of 1 kV to 36 kV a.c. (IEC 61243-2:2002, MOD) 

• CAN/ULC-61318-08, Live Working - Conformity Assessment Applicable to Tools, Equipment and Devices (IEC 61318:2007, IDT) 

• CAN/ULC-61328-09, Live Working - Guidelines for the Installation of Transmission Line Conductors and Earthwires - Stringing Equipment and Accessory Items (IEC TR 61328:2003, MOD) 

• CAN/ULC-61478-05, Live Working - Ladders of Insulating Material (IEC 61478:2003, IDT) 

• CAN/ULC-61479-05, Live Working - Flexible Conductor Covers (Line Hoses) of Insulating Material (IEC 

• CAN/ULC-D61481-06, Live Working - Portable Phase Comparators for Use on Voltages from 1 kV to 36 kV a.c. (IEC 61481-A2:2004, MOD) CAN/ULC-61482-1-1-09, Live Working – Protective Clothing Against the Thermal Hazards of an Electric Arc - Part1-1: Test Methods – Method 1: Determination of the arc rating (ATPV or EBT50 of flame resistant materials for clothing (IEC 61482-1-1:2009, IDT) 

• CAN/ULC-61482-2-09, Live Working – Protective Clothing Against the Thermal Hazards of an Electric Arc – Part 2: Requirements (IEC 61482-2:2009, MOD) 

• CAN/ULC-61911-05, Live Working - Guidelines for the Installation of Distribution Line Conductors - Stringing Equipment and Accessory Items (IEC TR 61911:2003, IDT) 

• CAN/ULC-62192-09, Live Working - Insulating Ropes (IEC 62192:2009, MOD) 

• CAN/ULC-62193-09, Live Working - Telescopic Sticks and Telescopic Measuring Sticks (IEC 62193:2003, MOD) 

• CAN/ULC-62237-09, Live Working - Insulating Hoses with Fittings for Use with Hydraulic Tools and Equipment

With so much at stake when maintaining electrical systems that the general population take for granted will always be up and running, the power line industry now has a revised standard to help ensure proper work habits, procedures and safety equipment will get workers home after a day’s work. In addition to the brief descriptions above, the CAN/ULC-S801 standard includes information on fall protection and use of PPE, worker and employer responsibilities, minimum approach distances and requirements for vegetation control work in the vicinity of overhead lines. 

The Committee on Electric Utility Workplace Electrical Safety: ULC-S800A mandate is to develop and maintain standard(s) pertaining to electric utility workplace electrical safety for generation, transmission, and distribution. If you require any additional information, please contact Gillian Ottley at 613-755-2729 ext. 61472 or by email at Gillian.Ottley@ul.com.

This standard can be ordered for $220 (Hardcopy) or $182 (PDF) at www.ulc.ca by selecting ULC Standards. Once on the ULC Standards homepage, select Sales of ULC Standards Materials

If you require any additional information regarding ULC Regulatory Affairs, please contact Pierre McDonald at 780-419-3202 or by email at Pierre.mcdonald@ul.com.


 

Pierre McDonald, CET, is Senior Regulatory Affairs Representative/Répresentant Principal, Affaires Réglementaires, Underwriters Laboratories of Canada Inc. Based in St. Albert, AB, Pierre has been a member of the Canadian Electrical Code Part 1 technical committee as well as several subcommittees including serving as Chair of Sections 6 and 76 and as a member representing regulators on several other CSA committees. Pierre is still active with code development and interpretation.

Other articles by Pierre McDonald:

2015 CE Code: Changes on “Approved Electrical Equipment” 

Code and Public Safety 

Section 62: Fixed Electric Heating Systems 

Establishing When the CE Code Becomes Mandatory 

UL Code Link 

CAN/ULC-S576-14, Standard for Mass Notification System Equipment and Accessories 

Canadian CE Code Changes: Section 20 and More 

Meeting National Building Code of Canada Requirements 

Conductor Ampacities and Their Temperature Rating

Codes and Standards - Provincial Legislation and the Administrative Requirements of the CE Code 

Changes to Section 12 Wiring Methods 

Section 4 Conductors — Changes from the Canadian Electrical Code’s 2009, 21st Edition to the 2012, 22nd Edition 

Title: Ready, Set, Scale: How to Grow Your Field Service Business

SimProThrough many trials and tribulations, you’ve grown your business to where it is today. It’s taken blood, sweat, tears, long hours and sacrifice. But, it’s all been worth it to have something which you can call your own. It’s even more worth it when you can finally take that next step to grow your business even further and expand your service, project and maintenance work.

Read More


 

Changing Scene

  • Prev
43 years ago, Steve Silverstein bought a table saw and a delivery van and began a revolution in the ...
E.B. Horsman & Son (EBH) has announced their Victoria location will be officially moving to a ...
 The Maritime’s largest Mechanical and Electrical event took place last Wednesday and ...
IDEAL INDUSTRIES, INC. is calling all professional and student-apprentice electricians to come out ...
Vivi White has been appointed to the Board of Directors of the Electrical Safety Authority ...
The Sonepar Ontario Region is proud to announce the relocation of their SESCO Central Distribution ...
The Electrical Safety Authority (ESA) is looking for a seasoned business executive drawn from an ...
David Rellinger, Vice President of Systems Transformation for Schneider Electric (SE), has been ...
The National Electrical Trade Council (NETCO) is pleased with the direction of the 2022 budget with ...
The Executive of Gerrie Electric Wholesale Limited is very pleased to announce the acquisition of ...

Become a Wiser Approved Installer

Schneider Wiser Installer

Get access to exclusive benefits, product discounts and resources that will help you drive more business, and lower energy bills for your clients.

 

 

 

Read More


 



Vivi WhiteVivi White has been appointed to the Board of Directors of the Electrical Safety Authority (ESA) by the Honourable Ross Romano, Minister of Government and Consumer Services.

“As Chair, I am pleased that the Ontario Government recently appointed Vivi White to the Board,” said Annette Bergeron. “The Electrical Safety Authority’s efforts over the years have greatly improved the safety of the people of Ontario. It’s an important mandate and requires a strong, talented and diverse board as we transform into a modern regulator.”

 

Read more


 

Omnicable joins ETIMETIM North America announced that OmniCable has joined the product classification standards organization. Headquartered in West Chester, PA, OmniCable has 24 locations throughout North America, and also owns Houston Wire & Cable (HWC). The company partners with many electrical manufacturers and only sells to distributors.

According to John Dean, Director of Marketing & E-Commerce, OmniCable/HWC, “The wire and cable industry is often called commodities, but there are very distinct features and attributes for the different products our manufacturers produce. 

Read More

 


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 

Switch to Smart, Switch to Easy, Switch to Beautiful

Schneider Connected LivingScrewless wall plates. Smart Outlets. Square D™ Switches and Receptacles are raising the bar on aesthetics, ease of installation, remote lighting control and connectivity.

 

 

 

Read More


 



 

FlukeElectrical distribution problems are not always immediately identified as issues with power quality. An example of this is a thermal-magnetic circuit breaker. When it trips, the indication is generally a short circuit, ground fault, or overload. At times this can be put down to an old breaker that needs replacing.

However, it’s important to investigate the types of loads on the system and monitor harmonics for a potential disturbance. This article explores common issues with power quality and how to troubleshoot those issues.

 

 

Read More


 

EIN Romex 12 2 Recall 400This recall involves a yellow electrical wire, 12/2 NMD90 75M Romex SIMpull cable, sold by the spool. Products were also sold at Home Depot designated as article 108196.  Only cables with a time stamp between 12:41 and 18:02 are affected by this recall. 

The recalled product contains a neutral wire that is a smaller 14-gauge wire, contrary to the stamp on the wire identifying both the neutral and “hot” wires as 12-gauge (i.e., "12/2"). 

The recalled product contains a 14-gauge neutral wire instead of 12-gauge (as labelled), thus it may not perform as expected in 12-gauge applications, resulting in a risk of those applications having impaired performance and/or compliance with safety codes or standards.

Go HERE for more information


 

Product News

  • Prev
Klein Tools introduces the new Advanced Circuit Tracer Kit, offering tracing of breakers and ...
The SYM-IN "In Table" model provides an attractive user interface while solid construction ...
The NEW Contractor Select™ version of the Juno Podz™ Canless Downlight is now easier than ever ...
Introducing the NEW Hi-Tech Valiant™ full-range current-limiting fuse for fire mitigation. No one ...
Appleton™ explosionproof and dust-ignition proof GR, GRF and GRTS conduit outlet boxes are ...
Southwire's new 100' LED string lights with 12,000 Lumens.    
Help provide comfort and functionality to your bathroom with the addition of the Broan BHF110 ...
The PWB-CMU8 is the first dedicated Masonry Wall Box engineered for installation in 8” block walls. ...
Now with pre-sized labels and even more materials to take on the toughest on-site labelling jobs. ...
The STACK Family is now complete! These four performance-tiered solutions were designed to help you ...

Liteline Continues Canadian Investment

EIN BC Liteline 400Adding continued investment in Canada to its core foundation of innovative Design, installation efficiency, and personal customer service, Liteline has just announced the opening of its 12,729 square foot Showroom and Lighting Distribution Center in Langley BC.

The new Liteline Facility is located at 26550 Gloucester Way, Unit A110 and will house the new Liteline Distribution Center along with a product showroom. 

Read More




Greenlee Mobile Bending Table for 881 Series Hydraulic BendersGreenlee is bringing secure and easy-to-transport conduit bending capabilities to jobsites with the introduction of its Mobile Bending Table for 881 Series Hydraulic Benders. The new product combines the latest in anti-theft protection with enhanced mobility, easy set-up and quick teardown.

“Electricians are constantly trying to do work more efficiently. Anytime we can shave time off a job, it’s a win – and this product delivers that with easier set-up and portability. At the same time, we know that protecting equipment from theft is an issue for a lot of tradespeople. The new Greenlee Mobile Bending Table for the 881 Series Hydraulic Benders is our latest solution to help professionals safeguard their investments and increase productivity,” 

Read More


 

 

Klein Tools Upgraded Testing KitKlein Tools introduces the Premium Electrical Test Kit.

Premium Electrical Test Kit (Cat. No. 69355)

  • Refreshed kit that features three new product releases geared towards a variety of electrical testing applications.
  • Kit includes instructions and all required batteries.

Manual-Ranging Digital Multimeter with Right-Angle Test Leads (Cat. No. MM320 – Exclusive to Cat. No. 69355 and Cat. No. MM320KIT)

  • Measures up to 600V AC/DC voltages, 10A DC current and 2-ohm resistance
  • Also tests batteries, diodes and continuity.

Read More


 

 

Brady M211Design, preview and print – all from your phone. Simple and intuitive, the M211 Label Printer is built for the job site, running all day on a full charge while resisting drops, shocks and crushes.

  • Simple. Easy. Intuitive.  Seamlessly design, preview and print labels from the industry leading Express Labels App on your familiar smartphone and swiftly connect to your printer.
  • Label it once.  Now with both pre-sized and continuous labels in 90+ cartridges, filled to the brim with reliable, tested and dedicated label materials that stay attached and remain legible on every surface and in any environment.

 

Read More


 

Peers & Profiles

  • Prev
Watt’s the Word is a recently launched Electrical Industry Podcast hosted by Zack Hartle and ...
Allana Kellett-Jamieson loves working in the electrical sector and is proud of the great focus ...
As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the ...
Karen Pullen knows what it’s like to be the only woman on a construction site, and as a proud ...
As of February 2021, Martin Stephenson is the new President and CEO of Signify Canada.   ...
This past July, Kerith Richards, who has worked for Service Wire Company for the last seven years, ...
EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After ...
Headquartered in Concord, Ontario, Mercury Lighting services national retail, ...
Among the recipients of the 2021 Clean50 Awards announced last month is Carolina Gallo, Vice ...
Sarah Silverstein is a principal with Liteline along side her two brothers Mark and Daniel. ...


Brent NeillyBy Blake Marchand

Brent Neilly is the Group Marketing Manager with Milwaukee, he has a background in business communications with a B.A. from Brock University, as well as experience working in the construction industry.

“When I joined TTI (Milwaukee’s parent company) it was kind of a perfect match, I had some marketing knowledge from my business degree and some industry experience from working in the trades.” Neilly gained his experience covering an area from Orillia to Timmins, Ontario when he first joined the company as a Field Sales Rep, as well as on their Job Site Core Trade Specialists in the GTA where he found his niche working with utility clients. 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2022 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil