Canadian Electrical Industry News Week

Jan 3, 2019

Bill BurrBy William (Bill) Burr


The Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook** but will hopefully provide some help in navigating, while reading the code. The 24th Edition of the CE-C, Part I, (C22.1-18)* is now available from CSA Group.

In this article: diagrams and appendices. The Diagrams section of the Code contains 10 diagrams that illustrate essential information referenced by various rules of the Code. Diagrams referenced by rules are considered normative (mandatory) elements of the Code.

Diagram 1, which is referenced by Rules 26-700, 26-720, 26-744, 38-023, 58-400, 78-052, 78-102, and 86-306, as well as Diagram 2 and Appendix B, provides face illustrations for the CSA configurations for non-locking receptacles based on nominal voltages and amperages.


Diagram 2, which is referenced by Rules 12-020, 26-700, 78-052, 78-102, and 86-306, as well as Diagram 1 and Appendix B, provides face illustrations for the CSA configurations for locking receptacles based on nominal voltages and amperages.

Diagram 3, which is referenced by Rule 14-102 and Appendix B, illustrates the ultimate point of conductor de-energization of a faulted circuit, downstream from the point or points marked with an asterisk.

Diagram 4, referenced by Rule 20-302 (2), illustrates the extent of the Zone 2 hazardous location from the open face of a paint spray booth.

Diagram 5, referenced by Rule 20-302, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for spraying operations not conducted in spray booths.

Diagram 6, referenced by Rule 20-302 (7), illustrates the extent of the Zone 1 and Zone 2 hazardous locations for spraying operations not conducted in spray booths, but with the ventilation system interlocked with the spraying equipment.


Diagram 7, which is referenced by Rule 20-034 and Part B of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for tank vehicle and tank car loading and unloading.


Diagram 8, which is referenced by Rule 20-034 and Part E of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for pumps, vapour compressors, gas-air mixers, and vapourizers outdoors, in open air.

Diagram 9, which is referenced by Rule 20-034 and Part J of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for container filling outdoors in open air.

Diagram 10, which is referenced by Rule 20-302 (3), illustrates the extent of the Zone 2 hazardous locations adjacent to openings in a closed spray booth or room.


The Appendices section of the Code contains both normative (mandatory) and informative (non-mandatory) appendices providing information associated with rules of the Code.


Appendix A - Safety Standards for Electrical Equipment is a normative section and lists the standards used to certify electrical equipment for the purpose of being “approved” as defined in Section 0. Note that adopted international standards listed in this appendix may include Canadian deviations, and compliance with them is required for implementation in Canada. Also note that CSA and other accredited standards development organizations (SDOs) may publish new Canadian standards for electrical equipment, or periodically amend or publish new editions of standards listed in this appendix, and they may be used for product approval purposes by accredited certification organizations. In accordance with the mandatory procedures in Appendix C, the SDO publishing or amending a standard must notify the project manager of the Committee on Part I for distribution to the committee.

Appendix BNotes on Rules is an informative (non-mandatory) section of the Code that provides information and illustrations clarifying various diagrams, tables and rules in the Code.


Appendix COrganization and Rules of Procedure is a normative (mandatory) section of the Code and outlines the structure of the Canadian Electrical Code, Part I Committee, sub-committees, Executive Committee and the Regulatory Authority Committee, as well as the operating procedures for developing the code. It includes:

• procedures for amendments to the Code, interpretations of the Code, and appeals, if procedures are not followed
• the format and Rule terminology of the Code
• procedures for inclusion of reference standards to Appendix A as noted above, a flow chart, and a declaration checklist
• a standard form for subcommittee reports
• a form to be used to request an amendment to the Canadian Electrical Code, Part I
• a guide to subcommittee chairs for evaluation of proposals and subcommittee reports


Appendix D - Tabulated general information is an informative (non-mandatory) section that provides 17 tables and 4 diagrams of tabulated general information.


Appendix E - Dust-free rooms is an informative (non-mandatory) section and outlines construction of dust-free rooms built adjacent to or as part of buildings that, by the nature of their use or occupancy, are subject to accumulations of dusts that may create a fire or explosion hazard, and allows you to supplant the requirements of Appendix J for Class II and Class III hazardous locations.


Appendix F - Engineering guidelines is an informative (non-mandatory) section and provides engineering guidelines for preparing descriptive system documents for intrinsically safe electrical systems and non-incendive field wiring circuits as referenced by Rules 18-002, 18-064, J18-002, and J18-064.

Appendix G - Electrical installations of fire protection systems is an informative (non-mandatory) section that lists requirements related to electrical installations of fire protection systems that are not governed by rules of the Canadian Electrical Code, Part I but are required by the National Building Code of Canada.


Appendix H - Combustible gas detection equipment is an informative (non-mandatory) section that lists requirements and recommendations for combustible gas detection equipment for use in explosive gas atmospheres as referenced by Rules 18-068 and J18-066.


Appendix I - Interpretations is an informative (non-mandatory) section and includes committee interpretations of the Canadian Electrical Code, Part I that have been requested in writing to the project manager of the Committee on Part I. The form of a question must be such that it can be answered by a categoric “yes” or “no”. These interpretations are based on rules in the 2015 Code, so rule numbering and content in the 2018 Code may differ from the 2015 edition.


Appendix J - Class and Division System Installations contains normative rules and informative notes to rules for additions, modifications, renovations to, or operation and maintenance of existing facilities employing the Class and Division system permitted by Rules 18-000 (3) 18-000 (4), 20-000 (2), and 20-000 (3). The rules of Annexes J18, J20, JD and JT of this appendix are normative (mandatory, and the notes and illustrations contained in Annex JB are informative (non-mandatory). Note: Annexes J18, J20, JD and JT, because of their length, will be discussed in future instalments.


Appendix K - Extract from IEC 60364-1 is an informative (non-mandatory) section that is an extraction from IEC Standard 60364-1 Chapter 13. Chapter 13 of Section 131 outlines the fundamental principles to provide for the safety of persons, livestock and property against dangers and damage that may arise in the reasonable use of electrical installations, and is quoted in the second paragraph of the Object of the Code.

Appendix L - Engineering guidelines is an informative (non-mandatory) section and provides engineering guidelines for determining hazardous area classifications in facilities where explosive atmospheres can occur, as required by Rule 18-004. This appendix can be used as a guide to classify both the zone system and the class and division system of hazardous locations.

Appendix M - Translated caution and warning markings is an informative (non-mandatory) section and provides a chart of caution and warning markings translated from English into French.

In the next instalment, we will be discussing Annex J18, of Appendix J.

* The source for this series of articles is the Canadian Electrical Code, Part I, (C22.1-18) published by CSA.

** Note the CEC Handbook is also published by CSA.

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

 

Changing Scene

  • Prev
  Glen Dimplex Americas is proud to announce that its Vancouver facility was recently ...
May 13 to 19 is Powerline Safety Week in Ontario, which is meant to inform people across the ...
Divisional Lighting Manager Salma Siddiqui, the initiative will focus on making Westburne the ...
As of April 30, Natural Resources Canada has new dry-type transformer energy efficiency ...
Ontario Power Generation (OPG), in partnership with the Six Nations of the Grand River Development ...
The Energy Council of Canada has chosen of Fort St. John, BC Mayor Lori Ackerman as Canadian Energy ...
The winners of the New Products Competition at the MCEE 2019 trade show were announced tonight; ...
The year was 2002: Jean Chrétien was Prime Minister, Avril Lavigne topped the charts, the ...
The company’s wholesale locations will be branded Robinson Supply, and the lighting and bath ...

Electrician Forum Brought to you by Schneider Electric

As industry experts you know the products you use everyday better than anyone and should have input on what information you receive about products and what could improve them.

Therefore, we want your insight on the biggest challenges or issues you face when installing loadcentres, breakers (CAFI, GFI's…) and other surge protection devices. We ask that you do not provide product specific details but rather your general issues and concerns or any questions that have come to mind while working with these product types. Provide us with your valued expert insight into the issues you have faced so manufacturers can better inform you about the installation and use of these products. Lets generate some discussion that will help guide the Industry.

Make your comments  HERE

 

ESA Powerline SafetyThe invisible impact of powerlines should never be underestimated. In the past decade alone, 19 people in Ontario have lost their lives from overhead powerline contact. May 13 to 19 is Powerline Safety Week, which is meant to inform people across the province to stay vigilant of powerlines when doing work at home or on the job.

"Our work in raising awareness of powerline safety won't be finished until there are zero injuries or lives lost from contact," says Dr. Joel Moody, Chief Public Safety Officer, Electrical Safety Authority (ESA). "All it takes is a misstep or careless error to change the life of you, your colleagues or family."



Read More

 

 

 

 

ABB Eco FactoryABB has an extensive portfolio of eco-efficient solutions and services that can help decouple economic growth from environmental impacts. In fact, over half of ABB's worldwide revenues are generated by technologies that combat the causes of climate change. The company’s goal is to increase this contribution from 57 percent in 2018 to 60 percent by 2020.

The company’s commitment to combatting climate change includes limiting the environmental impact of its own operations. ABB’s current target for climate action is to reduce its own GHG emissions by 40 percent by 2020 from a 2013 baseline.



Read More

 

 

Codes and Regulations Brought to You by the CSA Group

  • Prev
The Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the ...
The Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the ...
In this article: Tables — Part B. This section of the Code contains 99 tables of essential ...
In this article: Section 58 — Passenger Ropeways and Similar Equipment. Rule 58-000 ...
  Unauthorized CSA Group certification marks have been found on wiring by Triumph Cable ...
In this article: Section 52 — Diagnostic imaging installations. The CE code is a ...
In this article: Section 46 — Emergency Power Supply, Unit Equipment, Exit Signs, and ...
  In this article: Section 44 — Theatre Installations. The CE Code is a ...
CSA has published C22.2 No. 60947-7-3, the harmonized standard for low-voltage switchgear and ...
  Electric welders. The CE Code is a comprehensive document. Sometimes it can seem ...

 

Wind Energy

Canada’s wind energy industry further expanded its installed capacity in 2018, while solidifying its status as the lowest-cost source of new electricity generation. Newly commissioned projects brought total national wind energy capacity to close to 13,000 megawatts (MW). Meanwhile, competitive auction results in Saskatchewan and Alberta confirmed the wind industry’s ability to continue to deliver record-low prices.

The six wind energy projects that were powered up in 2018 added 566 MW of installed capacity — a continuation of steady growth that contributed to an average annual growth rate of 20% per year since 2008.

Read more about Wind Energy...

Tools for the Trade

  • Prev
  IDEAL Industries has introduced Combination Drill Taps to its tool lineup. Combining the ...
  Stripping and crimping device, 100 - 240 V input voltage, for insulated ferrules with a ...
Professional all-in-one cutter/stripper for coaxial and twisted pair cables     ...
  Klein Tools' Coax Explorrer 2 tests coaxial cable and maps up to 4 locations   ...
  Ideal Industries' T-14 wire stripper s are ideal for all professionals working within the ...
  The ATS850 conveyor eliminates all types of electro static discharge requirements. ...
  Lorik Tool & Automation has the experience and ability to manufacture a variety of ...
  Ideal Industries' 26 piece insulated Journeyman kit is ideal for new electricians or for ...
  Klein Tools Deluxe Fish Rod Set comes in 19 pieces that when assembled can fish wire and ...
  BendWorks Software was designed to help electrical contractors adopt this new process ...

Solar Cell

A joint research team has developed a new type of highly flexible and stable solar cell that could be used in wearable electronics.

The power supply is vital to the safety of wearable electronics. Perovskite solar cell (PSC) has been widely used to manufacture flexible batteries because it is highly efficient, cheap, and easy to use. Perovskite is a material with the same type of crystal structure as calcium titanium oxide.

The flexible substrate is the key factor to determine the performance of PSCs.

Read more about Flexible Solar Cells...

 

 

Product News

  • Prev
Expanding on its extensive product line for motion control applications, Sensata Technologies ...
AutomationDirect has added high-speed I/O modules and a serial communications expansion module to ...
Looking for a smart and efficient alternative to dynamic braking? Look no further. The R1000 ...
Thinking of upgrading your current system? Trying to keep your costs low? IDEC has the answers ...
The ABB ACQ580 variable frequency drive (VFD) for the water and wastewater industries ...
The popular, classic TWR LED wall pack luminaire now comes with adjustable lumen output technology! ...
EarthTronics expands its high-efficiency traditional wall pack series with a 12-watt ...
The dual-color WLS15 low-profile strip light from Banner Engineering is a durable yet lightweight ...
FLIR Systems have released the FLIR VP40, a non-contact voltage detector for use in North America ...
Belden Inc., has released its new portfolio of Safe-T-Line Circuit Integrity (CI) cables.   ...

Flir VP40FLIR Systems have released the FLIR VP40, a non-contact voltage detector for use in North America designed for field-troubleshooting and verification of residential, commercial, and industrial electrical installations. The VP40 makes it easy to quickly troubleshoot live and neutral wiring to ensure a safe job site.

With its built-in flashlight and CAT IV safety rating, the FLIR VP40 is a must-have for preliminary job site checks for live wiring. The durable, pen-sized tester quickly identifies the presence of AC voltage without contacting wires, even in the latest safety outlets.


Read More

 

 

 

Peers & Profiles

  • Prev
Michael Gindalang works for Dupar Controls as a panel builder for the elevator and keypad industry. ...
Energy Efficient Lighting is a LED lighting manufacturer with nearly 30 years of industry ...
Matt Stanson is a master electrician with over 30 years of experience. He now leads a team of ...
After eight months, 263 events, 17 broken clocks, and thousands of competitors, Ideal ...
The National Electrical Trade Council (NETCO) is an industry-funded, not-for-profit organization ...
After eight months, 263 events, 17 broken clocks, and thousands of competitors, Ideal ...
Born and raised in western India, Rupali’s passion for mathematics and science began at a ...
After eight months, 263 events, 17 broken clocks, and thousands of competitors, Ideal ...
Allison Wood and Dominique Rivet are two apprentices who had a wealth of career options available ...
  In a recent sit-down Electrical Industry Canada was able to learn a little ...

Copper $US Dollar price per pound


 

EHRCIn a recent interview with the The National Post, Electricity Human Resources Canada CEO Michelle Branigan said the need for workers in Canada’s electricity industry is “extremely critical.”

The industry directly employs almost 107,000 people, but less than 1 in 20 is aged 25 or under, only 1 in 4 is a woman, and just over 1 in 10 is from a visbile minority.

These statistics are from EHRC’s Workforce in Motion, a labour market intelligence research initiative for the years 2017-2022. The research report is a planning and informing tool for a wide range of electricity sector stakeholders and provides critical information to the sector for both short and long term resource planning.

Read More

 

 

Kerrwil Publications

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2019 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil