The electric shock hazard has been neglected.  Journeyman Electricians have accepted been shocked as part of the job, a “right” of passage, a badge of honour.  This has not been acceptable and Journeyman Electricians may not be aware of the long term sequela health effects of receiving multiple low voltage electrical shocks and how it may have impacted them.  With respect to treatment there is only a single formal recognized treatment centre in Canada, the St Johns Rehab Centre. Electrical Injury Program .

When a worker is exposed to the electric shock hazard there are two possible outcomes.  A shock is received and the worker survives or they die.  Electrical incidents statistics confirm that fatal electrical injuries from the shock hazard are occurring at an alarming rate, on average still once a day in North America.  What is not published in electrical incident statistics reports is the number of electrical workers that may suffer from the long term effects of receiving multiple low voltage (≤750V) shocks.  The medical term for this is “sequela.”

Sequela:  “A sequela is a pathological condition resulting from a disease, injury, therapy, or other trauma. Typically, a sequela is a chronic condition that is a complication which follows a more acute condition. It is different from, but is a consequence of, the first condition.” Wikepedia.

We know what the immediate short term effects of receiving an electric shock are, as I noted above you survive the electric shock or you die.  The table below lists the short term immediate effects of receiving an electric shock.

Table 1 – Immediate Effects of Electrical Current Flow Through The Human Body

Current mA (milli-amps)

Physiological Effect On Human Body

Human Perception & Effect On Human Body

< 1ma

None

Imperceptible

1 mA

Perception threshold

Mild sensation

1-10 mA

 

Painful sensation

10 mA

Paralysis threshold of arms and hands

Cannot release hand grip “no let go” threshold

30 mA

Respiratory paralysis

Breathing may stop

75 mA

Heart fibrillation possible

Heart action mis coordinated

250 mA

Heart fibrillation

Heart may stop

4 amps

Heart paralysis threshold

Heart stop for duration of current flow

5 amps or greater

Tissue burns

Most likely fatal vital organs are burned or damaged, can lead to amputation of limbs

 

Note

The amount of current, the current flow path through the human body, and length of time of current flows through the human body determines heart fibrillation probability.  Male and female body resistance will be different and added muscle mass increases conductivity.  Wet or dry skin at the point of current entry will impact current flow.  The number of times an electric shock is received impacts the long term effects and possibly sequela.

If you are a Journeyman Electrician reading this article you may have long term sequela from been shocked multiple times throughout your career, at 120VAC, 208VAC, 240VAC, 277VAC, 347VAC, 480VAC or 600VAC.  If you have some of the symptoms I list in this article you may want to follow up with your family physician.  The potential long term sequela from receiving multiple low voltage electric shocks may be psychological, neurologic or physical symptoms.

Listed below are some potential long term effects of receiving multiple low voltage shocks:

Psychological Symptoms:

Behaviour changes and attention span issues.  You may be irritable, get frustrated, experience anger and may be physically aggressive.  You may experience depression and posttraumatic stress disorder depending on whether you experienced “no-let-go” or became unconscious due to the shock exposure.  Other sequela may be: insomnia, anxiety, fear of electricity, panic attacks, guilt, and moodiness.

Neurological Symptoms: 

Memory loss, numbness, headaches, chronic pain, poor concentration, carpal tunnel, seizure disorders, dizziness, tinnitus, and tremor.

Physical Symptoms: 

Generalized pain, fatigue, exhaustion, reduced range of motion, contracture, night sweats, fever, chills or joint stiffness.

Based on research completed the effects listed will change or may be more severe dependent on the shock resulting from no-let-go, was the shock momentary contact, the path the current flowed through the body, duration and amount of current.  There are two hospitals that actually have electrical injury research and treatment programs: St John’s Rehab in Ontario (https://sunnybrook.ca/content/?page=sjr-patvis-prog-electrical) and the University of Chicago, Chicago Electrical Trauma Rehabilitation Institute (https://cetri.org/).

John Knoll’s Story:

John Knoll is a Master Electrician, and a Professional Electrical Contractor (PEC) with the Electrical Contractors Association of Alberta (ECAA) and resides in Edmonton, Alberta, Canada.  Unfortunately John is currently not working in the trade and is suffering from sequalae related to receiving multiple low voltage shocks while at work starting as an Apprentice and while he was a Journeyman Electrician.  I think the story of John’s career as an Apprentice Electrician and Journeyman Electricians is very common.  John worked in the non-unionized side of the trade for most of his apprenticeship and career. 

When I asked John about his exposure to shock he told me “as an Apprentice we played games in apartments while trimming out around being shocked at 120VAC with lighting circuits, we were not taught to fear electricity or respect it.  I was never concerned about 120VAC, 240VAC, I didn’t consider it an issue to receive those shocks.  I always said I would rather receive one knowing it was coming then not knowing.  So after tick testing, we would touch the wires, sometimes the tick tester lied and it was better to know it was coming.  It was the most we were able to do most times not being supplied the proper PPE or training to do our duties.”

John started in the electrical trade in 2005 and told me he worked energized on three phase 208VAC panelboards as an Apprentice a few months into the trade and had received shocks as early as the first week in the trade. 

John stated, “I was probably shocked up to 500 times.”  This may be hard to believe, but I have talked to other Journeyman Electricians who quote they were shock hundreds of times during their career. John quoted that “the Journeyman Electricians I worked with when I was an Apprentice never identified the hazards and long term effects around the electric shock.  There was no formal training and no personal protective equipment provided.  If we wanted a tick tester we had to buy them ourselves.”  “Live” work was not questioned, “we had to work energized, as we couldn’t de-energize parts of the job.  For example, working in the parkade or on house panels, I couldn’t turn off the power or the lights.  We cut in panels energized and rarely could turn off the power as it impacted the other trades.  I didn’t receive any training on lockout until I worked the last few months of my fourth period in the Union.”

I think John’s comments about working on energized conductors and circuit parts was and is still the norm in the industry.  Yes there have been changes in the last decade in Canada with the CSA Z462 Workplace electrical safety Standard published, but the focus unfortunately has been on arc flash and not shock.

The bottom line is Apprentice Electricians and Journeyman Electricians have been shocked as a normal condition of doing their jobs with a complete lack of awareness of the potential long term effects by receiving multiple low voltage shocks throughout their careers.  The American Electrician’s Handbook from 1942 to 1960 taught electricians that the human body could be used to detect voltages up to 250VAC by touching with the hands or for low voltages using your mouth to “taste” electricity.

In John’s case he was experiencing psychological, neurological and physical symptoms that he did not know where potentially attributed to receiving multiple low voltage shocks throughout his career as an Apprentice and Journeyman Electrician.  When I interviewed John and he discussed his injuries it was unbelievable, but based on information that I had over 10 years ago - published by Dr. Joel Fish, who at the time was practicing as the St Johns Rehab Centre in Ontario - the long term sequelae of electric shock are real.  What changed John’s perception of shock and his sequelae was when he told me he was shocked at 347VAC, he said that shock was different, “I was held and could not let go, I knew I was going to die and had no control of my body.  I was saved by gravity when I fell off my ladder.  I thought I was dying, the pain was unbelievable as I lost the ability to breath” and at that point, John said, “I had a newfound respect and fear of electricity.”

John moved on in his career and had his own company from 2010 until he could no longer work due to escalation in his symptoms after the shocks he received throughout his career.  He believes he started experiencing symptoms as early as 2 years into the trade and began seeking chiropractic and massage care more often.  A known relief of nerve pain that is caused by the long term sequelae of electric shock.   In 2016 his life started to change rapidly and looking back now he knows that the multiple electrical shocks he received led to his deterioration in mental and physical health, his personal life was directly impacted, becoming divorced from his wife and issues with his friend and business partner.

Why was John shocked at work?  His comments align with the results of a recent shock research project completed by Technical Safety British Columbia (TSBC, https://www.technicalsafetybc.ca/State-of-Safety-2018/safety-stories/electric-shock).  In February 2019, the TSBC  published a report related to the shock hazard in BC “Negotiating Safety – Understanding the Behavioral and Sociocultural Factors Related to Electric Shock.”  The report was based on interviews and surveys completed and quoted reasons why electricians have worked and continue to work energized as: Societal, Sectoral, Organizational, Interpersonal and for Individual reasons.  The report concluded that poor training, poor work practices, complacency, not refusing to work energized, “I thought someone else had turned off the power,” or peer pressure (e.g. loss of job, keep boss happy, rebuked by other workers) influenced why working energized was never questioned.

I believe John’s story is not an isolated case.  I believe there are hundreds, potentially tens of thousands of Journeyman Electrician’s in Canada, the USA, and Internationally that have long term sequelae and have not correlated them to receiving multiple low voltage shocks throughout their career.  The personal mental and physical health issues, impact on family and the potential impact on continuing in the trade and potential financial impacts are significant.  If you are a Journeyman Electrician and are experiencing symptoms listed in this article, they are most likely attributed to you receiving multiple low voltage electric shocks while working.

A big shout out and thank you to John Knoll for telling me his story, his drive, entrepreneurial spirit, his candor and sharing his emotions.

References:

1.“Long-term sequelae of electrical injury.”  Dr. Marni L. Wesner, MD MA FCFP DipSportMed, and Dr. John Hickie, MD, MSc, CCFP CCBOM.  Canadian Family Physician, CFP-MFC Official Publication of The College of Family Physicians of Canada, September, 2013. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3771718/.

2.Biophsical Injury Mechanisms in Electrical Shock Trauma. Raphael C. Lee, Dajun Zhang and Jurgen Hanning.  Annu. Rev. Biomed. Eng. 2000:2:477-509.

3. American Electrician’s Handbook, Tyrell Croft Consulting Engineers. Clifford C. Carr, E.E., P.E., Fifth Edition, McGraw-Hill Book Company, Inc., 1942.  “Measuring, Testing and Instruments, 158. Electricians often test circuits for the presence of voltage by touching the conductors with the fingers. 159. The presence of low voltages can be determined with tasting,”

4. Technical Safety British Columbia (TSBC) Electric Shock. https://www.technicalsafetybc.ca/State-of-Safety-2018/safety-stories/electric-shock

 

Terry Becker, P.Eng., CESCP, IEEE Senior Member is the first past Vice-Chair of the CSA Z462 Workplace electrical safety Standard Technical Committee and currently a Voting Member and Clause 4.1 and Annexes Working Group Leader.  Terry is also a Voting Member on the CSA Z463 Maintenance of electrical systems Standard and a Voting Member of the IEEE 1584 Guide for Performing for Arc-Flash Hazard Calculations.   Terry has presented at Conferences and Workshops on electrical safety in Canada, the USA, India and Australia.  Terry is a Professional Engineer in the Provinces of BC, AB, SK, MN and ON.  Terry is an Electrical Safety Specialist, Management Consultant, and can be reached at 1-587-433-3777 or by email terry.becker@twbesc.ca.

Changing Scene

  • Prev
Last week's disastrous floods have left many B.C. residents homeless, stranded or in desperate need ...
The Canadian Apprenticeship Forum (CAF-FCA) will launch a new program to empower skilled trades ...
Sean Dunnigan, President of Techspan Industries Inc., is pleased to announce the appointment of ...
The Electrical Safety Authority (ESA) would like to advise that the Minister of Government and ...
LabTest Certification Inc. is proud to announce its most recent recognition by OSHA as a Nationally ...
On November 13th, the Universal Women’s Network virtually hosted the 2021 Women of ...
Soussanna Karas, Director of Licensing at ESA, breaks down the risks of the underground economy ...
BCEA U40 group invites you to their Professional Development virtual series...     ...
Three accomplished women with diverse backgrounds are the newest members of Ontario Power ...


 

EIN ABB logo 400ABB is an international company with a large global presence, but did you know that a significant percentage of the products sold in Canada are also designed and manufactured locally?

ABB’s Installation Products division, formerly known as Thomas & Betts, operates seven manufacturing facilities in Canada, six of them in Quebec and one in Alberta.

Many of their most well-known brands, including IBERVILLE®️️, Marrette®️️, Microlectric®️️, and Star Teck®️️, are products that started in Canada and are still manufactured locally to meet Canadian standards.

 

 


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 



 

 Siemens Built In Isolation Products 400By Alyssa Kerslake

Life safety today is top of mind for nearly everyone. There is a certain level of trust that fire alarm systems continue to work within a fire incident. With system survivability being a key concern to regulators, building managers, and the public, Siemens has developed systems that are designed to meet and exceed regulations that protect people, property, and assets. 

One of the most significant concerns, particularly in a large multi-story building, is implementing a secure and fully functional fire alarm system. Today, it is not uncommon to have power and data for hundreds of fire alarm devices connected over a single pair of wires. The concern is, if a fault occurs somewhere between the devices, the zone and location of the device may no longer be known, or the operation of that circuit reduced or possibly impaired. These scenarios could allow an undetected catastrophic event to develop within the space due to inoperable life safety devices. 

 

Read More


 

 

David Gordon

By Terry Becker, P.Eng., CESCP, IEEE Senior Member

The CSA Z462 Workplace electrical safety Standard published its 2021 Edition in January.  A mandatory requirement for an employer is developing, implementing, and auditing an Electrical Safety Program.  If you have an Electrical Safety Program, is it up to date in its policies, practices and procedural requirements, is it performing as expected?  Workers do not necessarily do what you expect, they do what you inspect!  Management of change is required.

I have been involved in supporting industry with respect to shock and arc flash hazards in the workplace and in understanding what needs to be done to ensure worker safety, that effective defendable due diligence is established, and evidence of compliance is available related to occupational health & safety regulations both Provincial, Territorially or Federally.  I am in Ontario this week completing a detailed Electrical Safety Audit at multiple enterprise facilities.


Read More


 

Product News

  • Prev
On the hottest days of the summer and the coldest of the winter, the Napoleon NS18 heat pump and ...
Lumenwerx is pleased to launch Aera, an innovative lighting family that marks a new era in recessed ...
Eaton’s humidity sensor and fan control (HDFS3P1) device is a single pole humidity sensor for ...
With an EC motor and smart control, ORA-EC40 series air curtains are ideal for commercial and ...
Klein Tools expands its line of insulated screwdrivers with new lengths and tips, as well as a new ...
EarthTronics LED High Lumen Wattage & Color Selectable Series to provide flexibility and full ...
Eaton’s astronomic programmable timer (AT18HM) device reduces energy consumption by automating ...
The HomeGuard LED family of residential security lights, with rugged die cast aluminum ...
This preassembled constant wattage heating cable from Ouellet is specialized for roof and gutter ...


 

Milwaukee M12 Cable Stripper

Connect plug-in lamps, holiday lighting, and small appliances to the top “Controlled” outlet, while the bottom “Powered” outlet remains always on. The DW15R features tamper resistant receptacles with built-in shutters to prevent the insertion of unintended foreign objects. As well, the integrated button with vanishing feedback LED provides manual push-button on/off control and clear indiciation at any time.

Simplify control of the residence - schedule lamps and connected loads to turn on/off at specific times or based on sunrise/sunset, easily group smart devices into rooms, and create scenes to activate multiple loads at once. Utilize the auto-shutoff feature as a countdown timer in closets, hallways and bathrooms.

Read More


 

 

Incoplas Hybrid

Now available for Siemens Class 52 Actuators and Indicator Lights are the new Class 1, Div. 2 contact blocks. Suitable for use in Hazardous Location, Class 1, Div. 2 applications when used in a suitable enclosure. No matter which style actuator you use, the common base provided attaches to the hazardous location contact blocks easily.

Hazardous Location (HL) Series Contact Blocks are good for Hazardous Location CL1, DIV2 Applications using a Standard Enclosure NEMA 1, 12, 13, 4, 4X.

HL Series Contact Blocks are rated for switching high inrush loads like Tungsten Lamps.

 

Read More


 

 

EarthTronics 25-Watt Emergency Driver for Linear Highbay

The 20A Outlet and 15A Outlet have the ability to allow function specific Inserts to be installed/removed/swapped making this platform an optimal choice for renovations and new construction. The Swidget Outlet is installed using the same wiring as a standard wall receptacle and when paired with a Swidget Insert turns into a powerful and flexible Smart Home device. The swapability of the Inserts ensures that this will work with Smart Home wireless systems now and in the future.

The Swidget product line targets the Home Automation and Smart Home markets with a unique future-proof solution. Swidget currently offers eight smart Inserts with different functionalities including Wi-Fi control, indoor air quality sensor, temperature, humidity, and motion sensors, as well as a USB charger guide light, and emergency lighting. They can all be controlled from anywhere with the Swidget App for iOS/Android or Alexa and Google Home.

Read More


 

Peers & Profiles

  • Prev
Allana Kellett-Jamieson loves working in the electrical sector and is proud of the great focus ...
As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the ...
Karen Pullen knows what it’s like to be the only woman on a construction site, and as a proud ...
As of February 2021, Martin Stephenson is the new President and CEO of Signify Canada.   ...
This past July, Kerith Richards, who has worked for Service Wire Company for the last seven years, ...
EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After ...
Headquartered in Concord, Ontario, Mercury Lighting services national retail, ...
Among the recipients of the 2021 Clean50 Awards announced last month is Carolina Gallo, Vice ...
Sarah Silverstein is a principal with Liteline along side her two brothers Mark and Daniel. ...
As a 34-year-old female owner of an electrical contracting business, Danielle Gray may be unique. ...


EngWorksBy Blake Marchand

EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After a short time we realized there was a niche in hazardous locations, in particular in hazardous area classification design requirements for various facilities. And also helping people understand just how the Canadian Electrical Code applies to hazardous locations.”

Given the complexity of hazardous locations, Bozek saw a need for education while working in the field and began developing training courses designed.

Read More


 

Éric DeschênesBy Line Goyette

As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the electrical industry. He has a long track record and a passion for finding practical solutions to optimize technology adoption. Deschênes took on his current role with ABB January of 2020, he joined ABB in 2017 as Executive VP of the Electrification business after 15 years with Schneider Electric.

We met with him recently to discuss his new role at the helm of ABB Canada and his plans moving forward. He began by pointing out that the recent change to ABB Canada's structure, as elsewhere in the world, was made to make customer relations more straightforward. 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil