Canadian Electrical Industry News Week

October 22, 2021

Siemens Built In Isolation Products 400

By Alyssa Kerslake

Life safety today is top of mind for nearly everyone. There is a certain level of trust that fire alarm systems continue to work within a fire incident. With system survivability being a key concern to regulators, building managers, and the public, Siemens has developed systems that are designed to meet and exceed regulations that protect people, property, and assets. 

One of the most significant concerns, particularly in a large multi-story building, is implementing a secure and fully functional fire alarm system. Today, it is not uncommon to have power and data for hundreds of fire alarm devices connected over a single pair of wires. The concern is, if a fault occurs somewhere between the devices, the zone and location of the device may no longer be known, or the operation of that circuit reduced or possibly impaired. These scenarios could allow an undetected catastrophic event to develop within the space due to inoperable life safety devices. 

ISOtechnologyTM eliminates this concern by utilizing Fault Detection and built-in Isolation in each fire alarm device (i.e., detector, manual station, I/O modules, etc.). It identifies when a fault has occurred, reports the type of fault, and isolates as required. ISOtechnologyTM allows other devices on a common Data Communication Link (DCL) loop to operate when a fault occurs. Fault Isolation is one of the key requirements under the National Building Code and CAN/ULC-S524, and Siemens is the first major manufacturer to provide a system with built-in isolation in all major devices.

ISOtechnologyTM has proven to be reliable and secure, but the benefits go well beyond peace of mind concerning operational efficiency. ISOtechnologyTM is also extremely easy to install as it utilizes fewer devices, includes pinpoint wire-to-wire short identification, and can be added into existing Siemens various Control Units. 

To learn more about ISOtechnologyTM, we spoke with Jeffry Tondang, Product Manager at Siemens Canada. 

Q: What are the benefits of having built-in isolation in Fire Alarm devices?

With built-in isolation in fire alarm devices such as smoke/heat detectors, manual stations, input/output modules, the traditional isolator-only devices are no longer needed, and this comes with several benefits. For example, less engineering work, fewer devices (no isolator-only devices, backboxes, wiring, and associated labor) This would provide lower system life-cycle costs over the life of the system with savings in operational and maintenance costs.

Q: How is troubleshooting time decreased with ISOtechnologyTM?

When a fault happens, i.e., wire-to-wire short, short and ground, or short and open, the ISOtechnologyTM allows a technician to locate where the disconnect location is. The location, which is between two devices, will be made available at the control unit. Therefore, the technician can now concentrate on troubleshooting only between these two points. It removes the laborious and time-consuming process of elimination method, checking between one device to another. 

Q: Can the whole system still run efficiently if one fault, i.e., wire-to-wire short applied to the circuit? 

Yes. By setting all the ISOtechnologyTM devices as isolators, the system survivability is increased. Therefore, a single fault will not affect the operation of the fire alarm system at all.

Traditional System 400Image 1: A traditional fire alarm system with isolators.

System ISOTechnology 400

Image 2: A fire alarm system with built-in isolation “ISOtechnologyTM"

Q: How does pin-point wire-to-wire short identification reduce service time? 

When a wire-to-wire short happens within a wiring loop, the two devices adjacent to the short location on the wires will isolate themselves. These devices and location will be made known at the control unit. Then the technician will know where to begin troubleshooting efforts instead of searching for some time to find the location of the short.

Q: How would one go about expanding their already existing Siemens system?

This depends on the current system in the field, and there could be variations on how we could approach it. For example, if the system installed is an addressable legacy system, we will look for the most efficient way to migrate the head-end (or the control unit) then moving on to the devices as the field is ready. The process is much simpler for our most current fire alarm systems (i.e., earlier version without ISOtechnologyTM). The best way to find out how is by contacting our Branches or Partners in the area for solutions to your specific site design. 

Panel Isolation Compatibility on All Siemens SystemsTraditional vs ISOtechnology components

The image above depicts a traditional device in comparison to Siemens ISOtechnology devices with built-in isolation. Each of these devices are compatible with Modular, Compact, or 50 Point panels.

Q: How can end-users rest assured that they have a reliable system that has increased system survivability?

With built-in isolation, each device can be set or configured as an isolator, which is above and beyond the regulatory requirement. The code requires that each fire zone (i.e., 1 floor area) be isolated so that a fault within one floor area cannot affect normal operation of devices in another area. In other words, if a single fault happens on that floor, it is understandable if that floor is gone or no longer visible to the system, as long as devices on other floors are working normally. By setting all devices on that floor as isolator, if a single wire-to-wire short or open or ground happens between devices, all the devices on that floor are still working normally and communication to the control unit is still maintained, even when one portion of wiring in that floor is disabled. Therefore, the floor where the fault happened is still protected! Here is another additional benefit: when a zone or floor is no longer supervised by a fire alarm system, a Fire Watch (which could be costly) is required. With ISOtechnologyTM, owners of the property could avoid the unnecessary Fire Watch.

Survivability above and beyondISOtechnology improves system survivability

The image depicts how ISOtechnologyTM provides virtual circuit survivability and a short in one zone does not affect another zone or impede normal system operation. When the system remains fully operational when a single fault is applied, you increase life safety guaranteeing an alarm is always received at the fire alarm control panel. With all these elements in place, installers and end-users can rest assured that they have a reliable system that has increased system survivability. 

Implementing a secure and effective fire alarm system is one of the most important considerations for large multi-story buildings, and Siemens recognizes the importance of security and safety that comes with that. With ISOtechnology TM providing fault detection and built-in solation, the system’s overall safety and reliability is improved, especially in case of emergency. Users benefit from ISOtechnology TM since it not only enhances the safety system, but it also saves users’ time and money. 

For more information on ISOtechnologyTM       

 

 

To discuss adding ISOtechnologyTM to your system with a Siemens Branch or Partner in your area, click HERE

Alyssa Kerslake is an Associate Editor with Kerrwil Publications 

Changing Scene

  • Prev
Last week's disastrous floods have left many B.C. residents homeless, stranded or in desperate need ...
The Canadian Apprenticeship Forum (CAF-FCA) will launch a new program to empower skilled trades ...
Sean Dunnigan, President of Techspan Industries Inc., is pleased to announce the appointment of ...
The Electrical Safety Authority (ESA) would like to advise that the Minister of Government and ...
LabTest Certification Inc. is proud to announce its most recent recognition by OSHA as a Nationally ...
On November 13th, the Universal Women’s Network virtually hosted the 2021 Women of ...
Soussanna Karas, Director of Licensing at ESA, breaks down the risks of the underground economy ...
BCEA U40 group invites you to their Professional Development virtual series...     ...
Three accomplished women with diverse backgrounds are the newest members of Ontario Power ...


 

EIN ABB logo 400ABB is an international company with a large global presence, but did you know that a significant percentage of the products sold in Canada are also designed and manufactured locally?

ABB’s Installation Products division, formerly known as Thomas & Betts, operates seven manufacturing facilities in Canada, six of them in Quebec and one in Alberta.

Many of their most well-known brands, including IBERVILLE®️️, Marrette®️️, Microlectric®️️, and Star Teck®️️, are products that started in Canada and are still manufactured locally to meet Canadian standards.

 

 


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 



 

 Siemens Built In Isolation Products 400By Alyssa Kerslake

Life safety today is top of mind for nearly everyone. There is a certain level of trust that fire alarm systems continue to work within a fire incident. With system survivability being a key concern to regulators, building managers, and the public, Siemens has developed systems that are designed to meet and exceed regulations that protect people, property, and assets. 

One of the most significant concerns, particularly in a large multi-story building, is implementing a secure and fully functional fire alarm system. Today, it is not uncommon to have power and data for hundreds of fire alarm devices connected over a single pair of wires. The concern is, if a fault occurs somewhere between the devices, the zone and location of the device may no longer be known, or the operation of that circuit reduced or possibly impaired. These scenarios could allow an undetected catastrophic event to develop within the space due to inoperable life safety devices. 

 

Read More


 

 

David Gordon

By Terry Becker, P.Eng., CESCP, IEEE Senior Member

The CSA Z462 Workplace electrical safety Standard published its 2021 Edition in January.  A mandatory requirement for an employer is developing, implementing, and auditing an Electrical Safety Program.  If you have an Electrical Safety Program, is it up to date in its policies, practices and procedural requirements, is it performing as expected?  Workers do not necessarily do what you expect, they do what you inspect!  Management of change is required.

I have been involved in supporting industry with respect to shock and arc flash hazards in the workplace and in understanding what needs to be done to ensure worker safety, that effective defendable due diligence is established, and evidence of compliance is available related to occupational health & safety regulations both Provincial, Territorially or Federally.  I am in Ontario this week completing a detailed Electrical Safety Audit at multiple enterprise facilities.


Read More


 

Product News

  • Prev
On the hottest days of the summer and the coldest of the winter, the Napoleon NS18 heat pump and ...
Lumenwerx is pleased to launch Aera, an innovative lighting family that marks a new era in recessed ...
Eaton’s humidity sensor and fan control (HDFS3P1) device is a single pole humidity sensor for ...
With an EC motor and smart control, ORA-EC40 series air curtains are ideal for commercial and ...
Klein Tools expands its line of insulated screwdrivers with new lengths and tips, as well as a new ...
EarthTronics LED High Lumen Wattage & Color Selectable Series to provide flexibility and full ...
Eaton’s astronomic programmable timer (AT18HM) device reduces energy consumption by automating ...
The HomeGuard LED family of residential security lights, with rugged die cast aluminum ...
This preassembled constant wattage heating cable from Ouellet is specialized for roof and gutter ...


 

Milwaukee M12 Cable Stripper

Connect plug-in lamps, holiday lighting, and small appliances to the top “Controlled” outlet, while the bottom “Powered” outlet remains always on. The DW15R features tamper resistant receptacles with built-in shutters to prevent the insertion of unintended foreign objects. As well, the integrated button with vanishing feedback LED provides manual push-button on/off control and clear indiciation at any time.

Simplify control of the residence - schedule lamps and connected loads to turn on/off at specific times or based on sunrise/sunset, easily group smart devices into rooms, and create scenes to activate multiple loads at once. Utilize the auto-shutoff feature as a countdown timer in closets, hallways and bathrooms.

Read More


 

 

Incoplas Hybrid

Now available for Siemens Class 52 Actuators and Indicator Lights are the new Class 1, Div. 2 contact blocks. Suitable for use in Hazardous Location, Class 1, Div. 2 applications when used in a suitable enclosure. No matter which style actuator you use, the common base provided attaches to the hazardous location contact blocks easily.

Hazardous Location (HL) Series Contact Blocks are good for Hazardous Location CL1, DIV2 Applications using a Standard Enclosure NEMA 1, 12, 13, 4, 4X.

HL Series Contact Blocks are rated for switching high inrush loads like Tungsten Lamps.

 

Read More


 

 

EarthTronics 25-Watt Emergency Driver for Linear Highbay

The 20A Outlet and 15A Outlet have the ability to allow function specific Inserts to be installed/removed/swapped making this platform an optimal choice for renovations and new construction. The Swidget Outlet is installed using the same wiring as a standard wall receptacle and when paired with a Swidget Insert turns into a powerful and flexible Smart Home device. The swapability of the Inserts ensures that this will work with Smart Home wireless systems now and in the future.

The Swidget product line targets the Home Automation and Smart Home markets with a unique future-proof solution. Swidget currently offers eight smart Inserts with different functionalities including Wi-Fi control, indoor air quality sensor, temperature, humidity, and motion sensors, as well as a USB charger guide light, and emergency lighting. They can all be controlled from anywhere with the Swidget App for iOS/Android or Alexa and Google Home.

Read More


 

Peers & Profiles

  • Prev
Allana Kellett-Jamieson loves working in the electrical sector and is proud of the great focus ...
As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the ...
Karen Pullen knows what it’s like to be the only woman on a construction site, and as a proud ...
As of February 2021, Martin Stephenson is the new President and CEO of Signify Canada.   ...
This past July, Kerith Richards, who has worked for Service Wire Company for the last seven years, ...
EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After ...
Headquartered in Concord, Ontario, Mercury Lighting services national retail, ...
Among the recipients of the 2021 Clean50 Awards announced last month is Carolina Gallo, Vice ...
Sarah Silverstein is a principal with Liteline along side her two brothers Mark and Daniel. ...
As a 34-year-old female owner of an electrical contracting business, Danielle Gray may be unique. ...


EngWorksBy Blake Marchand

EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After a short time we realized there was a niche in hazardous locations, in particular in hazardous area classification design requirements for various facilities. And also helping people understand just how the Canadian Electrical Code applies to hazardous locations.”

Given the complexity of hazardous locations, Bozek saw a need for education while working in the field and began developing training courses designed.

Read More


 

Éric DeschênesBy Line Goyette

As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the electrical industry. He has a long track record and a passion for finding practical solutions to optimize technology adoption. Deschênes took on his current role with ABB January of 2020, he joined ABB in 2017 as Executive VP of the Electrification business after 15 years with Schneider Electric.

We met with him recently to discuss his new role at the helm of ABB Canada and his plans moving forward. He began by pointing out that the recent change to ABB Canada's structure, as elsewhere in the world, was made to make customer relations more straightforward. 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil